atcgcc

200kW Series

Category:
Product Number TP4-200-400
Maximum Power 200 kW
Input Voltage || Frequency  400VAC / 480VAC (3P+N+PE), 50/60Hz
Input Current || Breaker Rating 0 to 300A
Output Voltage 150 – 750 VDC
Output current 0 to 300A (200A | 250A Limited by Connector)
Power factor  > 0.98 
Efficiency  >94% at nominal output power 
Connectors Dual GB/T
Dual CCS
Cyclic Charge Mode CCS – 200 A || GB/T – 250A
Parallel Charge Mode  100 kW per Port
Connector cable length 5m
Weight 430kgs
Dimensions (L x D x H) 760 mm x 673 mm x 1800mm 
Charging Protocol Standards  Mode 4 – IEC-61851, ISO-15118, DIN 70121
Mode 4 – GB/T 18487 2015, GB/T 20234 2015, GB/T 27930 2015 
Insulation (input – output) >2.5 kV
Ingress Protection IP54, IK10
Operating temperature – 22 F to 131 F ( 30 C to 55 C )
Altitude < 2000m
Working || Storage Humidity ≤ 95% RH || ≤ 99% RH (Non-condensing)
Display 7’’ touch screen
Communication Protocol OCPP 1.6J
Access Control  RFID: ISO/IEC 14443A/B || Credit Card – Optional
Power Electronics Cooling Air Cooled
Regulatory Compliance CE || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012
Communication  Ethernet Standard 4G || Wi Fi (Optional)
Electrical Safety: GFCI RCD 30 mA Type A
Electrical Safety: Surge Protection 20 kA
Electrical Safety General  Over Voltage, Under Voltage, Over Current, Missing Ground
Electrical Safety: Output Short Output power disabled when output is short circuited
Electrical Safety Temperature Temperature Sensors @ Charge Coupler and Power Electronics
Emergency Stop Disables output power with emergency stop button

 